Print this page

TSB Document:

Affected Component: SUSPENSION

Summary
Complaint - AIRMATIC fault message in instrument cluster - Compressor inoperative, 40A compressor fuse possibly triggered. - Vehicle level is not adjusted correctly, the vehicle possibly leans at an angle Cause Moisture in the compressor freezes at temperatures below zero and may block the compressor. As a result, the starting current when the compressor starts up is too high. Fuse is triggered Remedy Replace compressor, fuse, and relay. Update software and SCN coding. Please invoice the case using damage code 32671 73. Addition: Unscrew pressure line between compressor and valve block and check for moisture. If there is moisture in the pressure line, it can be assumed that there is also moisture in the AIRMATIC valve block. Replace AIRMATIC valve unit.

Click a tab for more information.

Date Published
JAN 09, 2023
NHTSA TSB #
10231024
Find something helpful? Spread the word.