- March 22: FCA Recalls 318,000 Dodge Charger and Chrysler 300 Cars recalls | 39 days ago
- March 20: Dodge Hornet and Alfa Romeo Tonale Vehicles Recalled recalls | 41 days ago
- March 2: Dodge Journey Backup Camera Failures Investigated investigations | 59 days ago
Dodge TSB #0900916
2016 Dodge Durango
TSB Document:
Affected Component: ELECTRICAL SYSTEM
- Summary
- Re+G21:H21place Both Intake Variable Valve Timing Solenoids This bulletin involves replacing both left and right intake variable valve timing solenoids due to multiple DTCs. A small number of customers may experience a Malfunction Indicator Lamp (MIL) illumination or the engine runs rough. Upon further investigation the technician may find one or more of the following Diagnostic Trouble Codes (DTCs) set in the PCM: · P0017 - Crankshaft/Camshaft Timing Misalignment - Bank 1 Sensor 2. · P0019 - Crankshaft Position - Camshaft Position Correlation Bank 2 Sensor 2. · P000A - Bank 1 Camshaft 1 Position Slow Response. · P000C - Bank 2 Camshaft 1 Position Slow Response.