1993 Saturn SL2
1993 Saturn SL2 NHTSA Recalls
There are also 2 Saturn recalls » 3 defect investigations » for the Saturn SL2.
NHTSA Campaign #93V132000 ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR
352,833 vehicles recalled
1993 SATURN SL2 -- The generator electrical wiring is not protected against excessive current flow which may be caused by an electrical short circuit in the generator.
Should an electrical short circuit occur in thegenerator, the generator wiring harness would experience excessive current flow. Under certain conditions, enough heat could be generated to ignite surroundingmaterials. If this occurs, an underhood fire could result with or without theengine running and without prior warning.
The generator wiring harness will be replaced with one that will open as a fuse would under certain excessive current flow conditions. For detailed information & supporting documents, see the official NHTSA page concerning recall #93V132000 »
NHTSA Campaign #93V094000 ELECTRICAL SYSTEM:BATTERY:CABLES
14,459 vehicles recalled
1993 SATURN SL2 -- The positive battery cable terminal at the starter solenoid may be formed incorrectly. Incorrectly formed terminals can contact the starter solenoid housing and cause an electric short circuit.
An electrical short circuit between the battery cable andthe starter housing can result in an underhood fire.
Inspect and, if necessary, adjust the clearance between the positive battery cable terminal so that it does not contact the starter solenoid housing. For detailed information & supporting documents, see the official NHTSA page concerning recall #93V094000 »