Affected Component: EQUIPMENT
- Summary
- This Preliminary Information communication provides information to the technician the steps to diagnose and repair the concern of the display is showing 32° F (0° C) after a battery or reprogramming a module. The outside temperature will begin to update if driven above 20 mph for at least 5 minutes. If the vehicle speed drops below 20 mph, the timer will reset and the display will stop updating. Once the display starts to update it may take several more minutes of driving above 20 mph for the display to fully update. Also if the vehicle is shut off for more than 8 hours the display will update when the ignition is turned on.