Ford Recall : Fuel:Fuel Tank Assembly:Pipe:Filler:Neck
1995 Ford Contour
A static charge can discharge and serve as an ignition source for fuel vapors in the area of the filler pipe, resulting in a flash vapor ignition and a vehicle fire.
Fuel System, Gasoline — Storage — Tank Assembly — Filler Pipe And Cap
- Summary
- A metal shield on the outside of the plastic fuel filler pipe can develop a static electrical charge during refueling of the vehicle.
- Actions
- Dealers will inspect and, if necessary, modify the vehicles by adding a ground strap between the filler pipe shield and the body.