Typical Repair Cost:

$156.00

Average Mileage:

66,585 miles

Total Complaints:

26 complaints

Most common solutions:

  1. not sure (15 reports)
  2. replaced blower motor resistor (4 reports)
  3. replaced capacitor and heater module (3 reports)
  4. replaced blower motor (2 reports)
  5. have it fixed at a dealership and then fixed agian for free (1 reports)
  6. stop leaks from warped cowl (1 reports)
Pontiac Grand Prix AC / heater problems

AC / heater problem

This problem may be covered under warranty. Ask your Pontiac dealer.

Helpful Websites About 2004 Pontiac Grand Prix blower motor will not shut off

A D V E R T I S E M E N T S

problem #26

2009Sep 17

Grand Prix 3.8L V6

  • Automatic transmission
  • 85,175 miles

As you can imagine, I'm very upset that this problem keeps happening. I don't know if it's something else that causes these resistors to continue to mess up or it's the store I got them at (Advance Auto). PLEASE HELP!!! This is getting very expensive. Who wants to have to unhook the battery cable every time they need to run somewhere!!!!!!!!!!!!!!!!!!

Update from Sep 22, 2009: On September 18th, I went to a GM Dealership and bought a new heater motor for ($120.69) and a heater module for ($63.34). I got a local mechanic to install both of these in my car (it took about 25 minutes) and he only charged me ($20.00). Right away, I noticed that the noises that had been continuing when I only put in the module were gone. I don't know if it was the heater motor or the module I had been getting from Advance Auto. I think it was probably the heater motor. I'm hoping this fixed the problem, so I also hope you don't hear from me again.

agh1055

Manchester, KY, USA

SEND A COMMENT »
Add A Complaint
problem #25

2009Aug 28

Grand Prix 3.8L V6

  • Automatic transmission
  • 85,150 miles

This time, I took the part back to advance for a replacement. After receiving the part, I had it replaced on 09/11/09. The serviceman who had been unhooking it, so it wouldn't run my battery down must have felt sorry for me. He unhooked the old one and put the replacement one in free. STILL MORE TO COME!

agh1055

Manchester, KY, USA

SEND A COMMENT »
Add A Complaint
problem #24

2009Aug 22

Grand Prix 3.8L V6

  • Automatic transmission
  • 85,100 miles

I fixed the problem with the water coming in under the dashboard. I bought a new heater motor resistor on 08/22/09 and had it installed the same day. It lasted until 08/28/09 and quit again on my way to work. MORE TO FOLLOW!!!

agh1055

Manchester, KY, USA

SEND A COMMENT »
Add A Complaint

A D V E R T I S E M E N T S

problem #23

2009Jul 05

Grand Prix 3.8L V6

  • Automatic transmission
  • 85,000 miles

I had water coming under the windshield into the ac unit under the hood, so I figured that was the problem. MORE TO COME!

agh1055

Manchester, KY, USA

SEND A COMMENT »
Add A Complaint
problem #22

2009Jul 20

Grand Prix GTP SC 3.7L

  • Automatic transmission
  • 70,000 miles

I am so pissed off I always wanted a grand prix finally got one. I left work today and realized my fan was blowing at top speed when I turned it off I realized it wasn't on. I got home at 11pm and in my garage started pulling fuses until I got it one that turned it off. WTF how much is this B/S going to cost to fix !!!!! With the car completely off fuse out I put the fuse back in and the fan started right back up. They just don't make cars the way they used to. Is this the relay stuck does anyone know tell me so I can fix it my damn self. !!!!!

yazming

Youngstown, Ohio, USA

SEND A COMMENT »
Add A Complaint
problem #21

2009Jul 04

Grand Prix GT1 3.8L V6

  • Automatic transmission
  • 102,000 miles

I come home after working a long week at Fort Dix and I had to return the rental car back to BWI when I hop in my car to run my coworker to the airport i turned on my A/C and begin driving not thinking about anything until i was going down I95 and realize that my blower was blowing at full blast and i had it turned up two notches and I was like ok and then I turned it off and it was still blowing! So now im pissed!!! So I had thought that maybe i could remove a fuse to keep it from running down my battery and that didn't work either so at that point i removed the negative terminal and shut it off and then out of curiosity i connected it again and it begin blowing! SO NOW im really mad because it now said theft system disabled my starting of my vehicle! SO NOW I CAN"T START MY CAR....ughhhhhh!!! WTF NOW!!!! So i tried to see if I was able to get into my DIC but no luck and the damn manual didn't help a damn bit so now that damn factory theft system disabled my car and i also noticed that it was spitting out SERVICE ABS, SERVICE THEFT SYSTEM, SERVICE BRAKE SYSTEM, CHARGING SYSTEM FAILURE, and so forth and those have never come up before! I serviced my brake 4 months ago so now im like HOT under the collar because this is total bulls**t!!! Now I come to this site and read this and it totally made me even madder that this could have been a recall and taken care of by GM but now I see why they are bankrupt and in trouble with the consumer! That makes me positive that I won't EVER buy another GM vehicle in my life again! Consumers are usually right and if you don't cater to us then risk going out of business!

dh_33

Baltimore, Maryland, USA

SEND A COMMENT »
Add A Complaint

A D V E R T I S E M E N T S

problem #20

2009Mar 20

Grand Prix 3.8L V6

  • Automatic transmission
  • 96,313 miles

I too have the same problem with the blower not shutting off. I did attend a GM Dealership today and shared some of the complaints I had printed off this site with the Parts & Service Employees. Unfortunately for me I was advised the same as all of you that this was not a recall. Being the positive person that I am I ended up purchasing a control module for $96.52 CDN and took it home to install it myself (no need to pay someone $85 an hour). I was advised it should only take two beers to finish it by the service guy.

This module is still not installed as of yet. It would appear as the person who designed the location of the module must have been drinking too. It is wedged tight up against the firewall and for some reason GM decided to cheap out and put some kinda bull sh*t plastic rivet to secure the factory module.

I am frustrated and my back is sore. If anyone out there knows hows these stupid rivets come off please let me know it would be appreciated. I don't figure I will get a response from a GM worker ....there probably drinking.

Greg D.

Toronto, Ontario, Canada

SEND A COMMENT »
Add A Complaint
problem #19

2009Apr 24

Grand Prix V6

  • Automatic transmission
  • 64,000 miles

As you can tell this is a big problem with all the complaints. This should be a recall. No wonder GM is going under when they don't stand by their product.

Jane R.

Oak Lawn, Illinois, USA

SEND A COMMENT »
Add A Complaint
problem #18

2009Mar 02

Grand Prix GTP

  • Automatic transmission
  • 43,496 miles

I did an oil change, and checked the cabin filter which was completely black with mold. This was a result of the cowling being warped and rain / windshield fluid leaks down into the filter (making it moldy), then down into the blower motor / blower resistor compartment, which will short out either or both components. I had to replace my resistor and I plan to do what it takes to prevent leaks in the cowling. A good thing to do before replacing the resistor is to also check the Amperage draw of your blower motor and make sure it's in spec. The FLA rating should be on the blower motor housing. If your draw is greater than the FLA on high fan speed, you may need to replace the blower motor as it is drawing too much power will blow your resistor.

cbrown54

Regina, SK, Canada

SEND A COMMENT »
Add A Complaint
problem #17

2009Feb 10

Grand Prix GT2

  • Automatic transmission
  • 90,000 miles

This is ridiculous... I just bought my car. I had the car for 2 weeks and the blower motor just keeps running. First it wouldn't work at all and then I got in my car the next day and it wouldn't shut off!! I have to unplug the battery every time I get out of my car!! This should be a recall as I have seen many other people with the same complaint!

halley

Janesville, WI, USA

SEND A COMMENT »
Add A Complaint

A D V E R T I S E M E N T S

problem #16

2009Feb 02

Grand Prix GT2 3.8L V6

  • Automatic transmission
  • 32,933 miles

OBVIOUSLY THIS IS A PROBLEM THAT GM HAS WITH THE GRAND PRIX, ALONG WITH OTHERS.....THE THING THAT REALLY PISSED ME OFF WITH THIS ISSUE WAS THE DEALERSHIP WAS A REAL PAIN IN THE ASS. IT TOOK THEM OVER A WEEK TO GET THE PARTS AND I GOT NOTHING BUT EXCUSES FROM THEM. W/E SH*T HAPPENS I JUST WANT TO DRIVE MY CAR FOR MORE THEN TWO WEEKS AT A TIME BEFORE IT GOES INTO THE SHOP AGAIN!!!!

c_haimes

Winnipeg, MB, Canada

SEND A COMMENT »
Add A Complaint
problem #15

2009Feb 02

Grand Prix GT 3.8L V6

  • Automatic transmission
  • 78,000 miles

I got in my car and it turned on full blast (luckily the battery was not already dead like some others), and when I stopped it did not go off. So I called the dealership and told him. He said he has had some similar problems and told me it was a resistor. I am not sure if he is correct, but he looked through his wiring diagram and told me to pull the fuse (under the hood) #30. It is a 30 amp battery main 4 I believe. He said it may reset my radio, but it did not. This keeps the fan off and does not run down the battery. This is easier than unhooking your battery. I have not had it in to the shop yet, but will soon.

Update from Dec 27, 2009: I had it fixed and it worked fine for a while, and then the fan went out. I am pretty sure it is getting shorted out due to water getting where it should not be getting. They did replace some cowling to keep water from going in the wrong place. The good news for me is that things that repeatedly go wrong are under a one year parts and labor warranty. So in the end for this particular problem (seems to re-occur and in shorter time than a year), I say pay to have it fixed once and then hopefully get it fixed for free. If it continues to go out you will save money in the long run.

Nathanael C.

Bainbridge, IN, USA

SEND A COMMENT »
Add A Complaint
problem #14

2008Dec 13

Grand Prix GT 3.8L V6

  • Automatic transmission
  • 52,000 miles

Same Thing is happening with my car as everyone else on here

Cullen C.

Glendive, MT, USA

SEND A COMMENT »
Add A Complaint
problem #13

2008Oct 11

Grand Prix GT 3.8L V6

  • Automatic transmission
  • 54,500 miles

I just had the same problem but have not fixed it yet. I hate you GM. I have tried to pull all fuses and relays related to fans and HVAC and nothing shuts it off besides disconnecting the battery. So I keep the blower unplugged under the dash.

I found a Technical Service Bulletin (link at bottom of complaint) and I purchased a capacitor ($15 new) and a blower module ($30 used). Have not replaced yet and hope it works but.....Complaint #7 gives good info. This person helped me realize that the cowl on the bottom of my windshield is also warped and does not seal out water which probably causes the blower motor to short out and ruin the logic in the blower module. I will attempt to replace the module and install the capacitor and find a way to seal out the water. If I fix the problem I will try to respond back with the details.

http://www.batauto.com/Forums/index.php?topic=377.0 <---TSB link

erock

Avon Lake, OH, USA

SEND A COMMENT »
Add A Complaint

A D V E R T I S E M E N T S

problem #12

2008Sep 29

Grand Prix GT 3.8L V6

  • Automatic transmission
  • 120,000 miles

I started my car yesterday and my ac/heater blower was on full bore making a loud noise ... i hit under my dash and the noise stopped but the blower didn't, now i shut my car off and the blower stayed on. WHAT THE HELL IS THIS SH*T?

harman

Erie, PA, USA

SEND A COMMENT »
Add A Complaint
problem #11

2007Oct 06

Grand Prix GT2 3.8L V6

  • Automatic transmission
  • 91,000 miles

I've found enough info on this on the web that this issue really needs to be a recall.

mnhockey99

Coon Rapids, MN, USA

SEND A COMMENT »
Add A Complaint
problem #10

2008Apr 02

Grand Prix GTP 3.8L S/C

  • Automatic transmission
  • 48,300 miles

This is the best place to try to fix something, I am gonna need a new back after change the module. Why the f didn't they use a bolt or screw its some plastic thing i am just about to the point where i pull it off with pliers

patt1982001

Enterprise, Alabama, USA

SEND A COMMENT »
Add A Complaint
problem #9

2008Apr 02

Grand Prix GT 3.8L Series3

  • Automatic transmission
  • 70,836 miles

I'M SICK AND TIRED OF PAYING FOR GENERAL MOTORS MISTAKES. THIS HEATER PROBLEM IS A COMMON COMPLAINT, EVERYONE I TALK TO HAS THE SAME PROBLEM,THEREFORE THIS SHOULD HAVE BEEN A RECALL! WHY IS THE CONSUMER STUCK WITH PAYING THE BILLS FOR GM'S MISTAKES,NO WONDER THE JAPANESE MARKET IS TAKING OVER. I HAVE BEEN A GM MAN MY ENTIRE LIFE AND BUY ALOT OF VEHICLES INCLUDING THE CORVETTE WHICH IS THIER FLAGSHIP OF CARS,BUT THEY BETTER GET THEIR ACT TOGETHER SOON OR THEY WILL BE LOSING ALOT MORE MARKET SHARE! AFTER FIXING THE HEATER ON THIS GRAND PRIX I FIND NOW THE TEMP. CONTROL DOES NOT WORK,ANYONE KNOW WHY THIS WOULD BE,THANKING YOU A. EHLER

aehler

Whycocomagh, N.S, Canada

SEND A COMMENT »
Add A Complaint
problem #8

2007Aug 17

Grand Prix GTP Comp G 3.8L SC

  • Automatic transmission
  • 39,000 miles

Last summer i went out to take my Grand Prix for a drive, and it was dead. It doesn't get driven often, and spends its life in the garage. I was surprised when it didn't start, especially when i know that the car is equipped with Battery Rundown Protection. I put it on the charger and heard the fan running, and the key was in my pocket. I looked closer, and i found the fan control off, and the ignition off. I have placed a switch in the ground circuit for the blower motor and attached it to the lower IP out of sight. I have not looked at it in much detail, as i don't drive it often, and don't think about it. I saw that someone had replaced the blower motor and module, as well as repair a leak that is causing the issue. I am going to look into this issue and will report back soon. If you have any suggestions, please let me know.

Eric S.

Winston Salem, NC, USA

SEND A COMMENT »
Add A Complaint
problem #7

2007Aug 22

(reported on)

Grand Prix GT 3800

  • Automatic transmission
  • 80,000 miles

At 79,000 miles on my grand prix the blower motor would not shut off even with the key out. I replaced the blower motor module, and 2000 miles later the same thing happened again. This time i replaced the module and blower motor. I think though i have found what everyone is looking for. The cowl is warped from the sun from poor mounting by GM. There is water pouring in from the cowl when it rains. the cabin filter sits right there collecting water and below that is the blower motor which the water is shorting out and the module. The cabin filter is full of black mold which i will be taking up with GM. SO EVERYONE OUT THERE LETS PULL TOGETHER TO GET THESE CARS RECALLED BEFORE SOMEBODY BECOMES VERY ILL. ALSO TO STOP THIS ANNOYING AND EXPENSIVE PROBLEM.

Greg P.

Washington, MI, USA

SEND A COMMENT »
Add A Complaint
problem #6

2006Dec 13

(reported on)

Grand Prix

  • Automatic transmission
  • 36,400 miles

The blower motor will not shut off on my 2004 grand prix gtp comp untill the battery is dead. I have read other complaints where the same thing is happening to others, but i still haven't found out what they did to fix it. So if someone knows would you please share that info with me?The warranty just ran out, so i need help figuring out the problem. thanks SheilaC

Sheila C.

Lorain, OH, USA

SEND A COMMENT »
Add A Complaint
problem #5

2006Dec 05

(reported on)

Grand Prix GTP 3.8L V6

  • Automatic transmission
  • 71,000 miles

Went to start my car this morning. The battery was dead. I charged it and noticed that the fan was running as the battery was charging. Completed the charge and disconnected the charger from the battery. The blower was still running. I attempted to turn it of by turning the knob counter clockwise into the off position. The blower continues to run. I also noticed that my steering column is not locked, as it usually is when the key is out of the ignition.

I assume that this is why my battery is dead (non stoppable blower).

J L.

Clinton Township, MI, USA

SEND A COMMENT »
Add A Complaint
problem #4

2006Sep 22

(reported on)

Grand Prix

  • 35,000 miles

Sept. -a week later Happened again. This time replaced blower motor. I've learned how to disconnect it. Very simple to do but an inconvenience with making an appointment and being without a vehicle.

Kim T.

Martins Ferry, OH, USA

SEND A COMMENT »
Add A Complaint
problem #3

2006Sep 22

(reported on)

Grand Prix

  • 36,000 miles

Sept.- Blower on again. This time the module was replaced and the capacitor.

Kim T.

Martins Ferry, OH, USA

SEND A COMMENT »
Add A Complaint
problem #2

2006Sep 22

(reported on)

Grand Prix

  • 35,000 miles

blower motor on high and would not shut off even with the car turned off. Purchased in Feb., problem started in July ( still under warranty). They said that the fire wall was down and maybe some water shorted out the wiring. Replaced the module.

Kim T.

Martins Ferry, OH, USA

SEND A COMMENT »
Add A Complaint
problem #1

2006Aug 17

(reported on)

Grand Prix LX

  • 45,000 miles

blower will not shut off even with key out fixed once before under warranty then but now out of warranty I cannot afford to pay a large amount. what are options? dealer says they will look at it but with no warranty what do I do? I am currently removing the battery cable to shut it down. is this harmful to my car?

pappap999

California, PA, USA

SEND A COMMENT »
Add A Complaint

We have partnered with JustAnswer to offer online auto repair help and advice from expert professional automotive technicians. You describe your AC / heater problem or ask your question and they try to help you figure it out. The fee is typically $9 to $15, but you can offer to pay more for really tough questions. You will usually receive an answer in 10 minutes or less, and you do not have to pay anything unless you accept the answer.